PD-169 Issue 3B Installation Guide Page 10 of 56
Compatible Phones
Model
Priva
cy of
Speech
Buzzer mute
Door
open
indicator
Slide
switch
(
on/off
)
Button with indicator;
adjustable mute time
801
x x x x
801S
x x x
801P
x x x
801PS
x x
BS-LX
x
Phones connected to a DBA-4I Phone Isolator have privacy of speech inherent in the design
therefore models 801P and 801PS should not be used. All phones connected to the same
DBA-8Z Isolator must be the same model (a mixture of desk or wall mounting is allowed).
As standard a maximum of two phones are allowed in each flat. Contact your distributor if
more are required.
The phones specified above are wall mounting. For a desk-mount model, add ‘–DESK’ to any
of the 801 phone series part numbers.
Phones can be supplied with a hearing aid induction loop fitted: add ‘-IDL’ to the part number.
Privacy of Speech
Once a call has been initiated from an entrance panel only the phones which are ringing may
answer the call. The conversation cannot be overheard by another phone except an
extension phone in the same flat (i.e. one which had also been ringing). This feature is
available on systems with Full Isolation (all phone models) and on Zonal Isolation (801P,
801PS and BS-LX models only).
Extension sounders and flashing strobe
The RT27 extension sounder can be fitted instead of a 2
nd
phone and has a similar volume
level and sound to the 801 series phones.
The SG1 sound generator has an adjustable volume level and 8 different tones. The volume
is louder than an RT27, but requires an extra 12V DC power supply such as a model 340C.
This power supply should be fitted close to the SG1. There is a maximum of 3 units per flat.
A FB31 flashing beacon is also available for the hard of hearing. The device requires an extra
power supply such as the 340C which should be a short distance from the FB31. There is a
maximum of 3 units per flat.
Note it is not possible to have a DBA-4I or DBA-8Z Isolator phone output connected to just
extension sounders or a strobe, a phone must be present.