PD-169 Issue 3B Installation Guide Page 9 of 56
Other third party readers can be accommodated depending on the size and fitting required.
Control units
All control equipment must be placed in a protected indoor environment or enclosure.
Part No.
Description
BSD-DIG Digital door controller (1 required per entrance panel)
DBA-4I 4 Way phone isolator (1 required every 4 flats)
DBA-8Z 8 Way zone isolator (1 required every 8 flats)
TS2000-BST Time clock with BST correction (1 required per system for trades
facility)
Various options are available when the control equipment is placed in one of our Steel
lockable cabinets; please contact your sales representative for advice.
Power Supplies
Please refer to the safety information at the end of this literature
Part No.
Description
PS4 12V DC 4A Regulated power supply
840 12V DC 3A with battery backup (requires a BAT01 12V 7AH battery)
BAT01 12V 7AH Lead acid battery
Power Supply Requirements (refer to overview drawings starting page 14)
1 x PS4 or 840
1 entrance + 32 phones
2 entrances (2 x BSD-DIG)
64 Phones:
8
4
16
8
DBA-8Z Isolators
DBA-8Z Isolators
DBA-4I Isolators
DBA-4I Isolators
with
with
with
with
1 phone in each flat
2 phones in each flat
1 phone in each flat
2 phones in each flat