Digibell Vandal Resistant System
PD-169 Issue 3B Installation Guide Page 23 of 56
Settings
ACOD 1234 Coded access code – must be 4 digits
TCOD 6789 Trade access code – must be 4 digits
LTIM 0003
⇑
Lock Time: 1-99 seconds
LOCK Secr Lock Type: Secr (fail secure), Safe (fail safe)
CAM2 No Not used
TRAD 0005 Trade Function: 0-9 – see table
DMON
Cwo Door Monitor Polarity: Cwo, Owo
RECP 9898 Reception / Porter phone number
PSEC 3434 Panel security code
PPRG 1212 Phone programming security code
RING 0015 Ring Time – see table
TALK 0015
⇓
Talk Time – see table
TONE Both Ring and Lock Buzz-Tone enable, 4 settings
CANC Yes Not used
BCAL No Not used
12A? No Allows user entry of 12A to call DBA-xx output 13
ACOD – Primary Access Code
This is the main code to open the door. It is required when the display prompts with [CODE]
after pressing the Trades button. The parameter ‘TRAD’ must be set to ‘Code’ or ‘Trade’ as
per the table below.
The code must be 4 digits and no letters, leading 0 is OK (e.g. [0246]).
TCOD – Secondary Access Code or Tradesmen’s Code
This is the tradesmen’s or secondary code to open the door. It is required when the display
prompts with [CODE] after pressing the Trades button. The parameter ‘TRAD’ must be set to
‘Trade’ in the active Time Clock setting, as per the table below.
The code must be 4 digits and no letters, leading 0 is OK (e.g. [0137]).
LTIM – Lock Release Time
Door unlocked duration. Range 1 to 99 seconds. Only the last 2 displayed digits are used.
A value of 0 will default to 1 second and a value containing alpha characters will default to 3
seconds.